Audited by an independent third-party inspection agency
High Quality Class B table top autoclave sterilize dental Autoclave, 18 & 23L, LCD display
Sterilization Class | CLASS B |
Sterilization Temperature | 121ºC &134ºC |
Special Program | HIV, HBV long-sterilization program |
Dry System | Vacuum drying system |
Display | LCD display |
Languages | English, Spanish, Italian, French, Portuguese, Ruassian |
Testing System | Bowie&Dick Test Vacuum Test Helix Test |
Control Precision | Temperature: 0.1ºC Pressure: 0.1Kpa |
Sterilization Data | Built in printer |
Safety System | Relief valve Hand lock door Pressure or temperature over load protection Alarm system |
Water Supply System | Build-in water tank easy to clean Cubage: 3.5 or 4L |
Tray Holder | 5 layers tray holder with 3 trays |
Chamber | Medical stainless steel 304 Max working pressure:2.3bar Min working pressure: -0.9bar Max temperature: 145ºC |
Operation Temperature | 5~40ºC |
Noise | <50db |
Water consumption in one cycle | 0.16L~0.18L |
Color | Purple, Green, Grey |
Program | Temp. | Pres. | Vacuum Times | Sterilization Time | Drying Time |
EMERGENCY | 134ºC | 210kPa | 1 | 4 min | 8 min |
SOLID | 134ºC | 210kPa | 1 | 4 min | 8 min |
HOLLOW | 134ºC | 210kPa | 3 | 4 min | 10 min |
SANGUINARY | 134ºC | 210kPa | 3 | 18 min | 10 min |
SOLID | 121ºC | 110Kpa | 1 | 20 min | 8 min |
HOLLOW | 121ºC | 1100Kpa | 3 | 20 min | 10 min |
GLASS | 121ºC | 110Kpa | 1 | 20 min | 8 min |
TAMPON | 121ºC | 110Kpa | 3 | 30 min | 18 min |
TEST B&D | 134ºC | 210Kpa | 3 | 3.5 min | 3 min |
TEST HELIX | 134ºC | 210Kpa | 3 | 3.5 min | 3 min |
TEST VACUUM | |||||
USER- DEFINED |
Model | Voltage/Power | Chamber Size | Outside Size | Packing Size | Net Weight |
Z-CLAVE IIB18 | 220V/1500W | Φ245×360 | 560×450×400 | 660×525×495 | 47 |
Z-CLAVE IIB23 | 220V/1700W | Φ245×470 | 670×450×400 | 770×530×495 | 53 |
Directive or Standard No. | Directive or Standard Name |
MDD 93/42/EEC | Medical Device Directive |
PED 97/23/EC | Pressure Equipment Directive |
EN 61010-1 | Safety regulations for electrical measuring, controlling and laboratory Devices- Part 1: General requirements |
EN 61010-2-040: | Safety requirements for electrical equipment for measurement, control and laboratory use -Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
EN 13060 | Small steam sterilizers |
EN 61326-1 | Electrical equipment for measurement, control and laboratory use - EMC requirements |
Quality System No. | Quality System Name |
ISO 9001 | Quality management systems-Requirements |
ISO 13485 | Medical device-Quality management systems-Requirement for regulatory purposes |